Sign In | Join Free | My portofva.com
China Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd. logo
Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd. an exclusive current transformer, split core current transformer, current clamp & voltage transformer manufacturer.
Active Member

8 Years

Home > Electric Meter Calibration >

TFT Display RS232 Active Electric Meter Calibration 70Hz

Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
Contact Now

TFT Display RS232 Active Electric Meter Calibration 70Hz

Brand Name : GFUVE

Model Number : GF312D1

Place of Origin : BEIJING,CHINA

MOQ : 1SET

Payment Terms : T/T, Western Union, MoneyGram

Supply Ability : 1500SETS/MONTH

Delivery Time : 1-2WEEKS

Packaging Details : CARTON

accuracy : 0.05%, 0.1%

display : 6”TFT (640×480)

power supply : 220V±10%, 50/60Hz

communication port : RS232

voltage range : Phase to Netural 0-480V (Phase to Phase 0-830V)

current range : 0-12A

harmonics : 2nd-64st

frequency : 40-70Hz

dimension : 245×162×60

weight : 1.8kg

Contact Now

FEATURES

  • Three phase active or reactive electricity energy meter.
  • Calibrate three phase, single phase, and active or reactive meter error.
  • Measure U(voltage) of three phase or single phase.
  • Measure I(current) of three phase or single phase.
  • Measure active power of three phase or single phase.
  • Measure reactive power of three phase or single phase.
  • Measure apparent power of three phase or single phase.
  • Measure power factor of three phase or single phase.
  • Measure phase angle between voltage and current.
  • Measure frequency of power line.
  • Display vector diagram.
  • Display waveform of U and I.
  • Analyze and display content of harmonic of U and I.
  • Measure 2-64 harmonic of U, I.
  • Store and display measured data.
  • Optional 5A, 20A, 100A, 500A, 1000A, 2000A, 3000A current clamp.
  • Measure CT variable ratio.
  • Measure the ratio or lag-angle of low-voltage transformer.
  • Adopt 32 bit ARM processor, multi-channel 16 bit precision A/D convertor, high resolution TFT color LCD.
  • Inner equipped with 0.01% wide-range current transformer and can be equipped with various type current clamps, wide range of measurement and high veracity.
  • Low consumption circuit design, high energy Lithium battery supply, intellectual power management software, which enables the instrument continuously working up to 10 hours.
1.Electrical parameters 
Accuracy class 0.05%, 0.1%
Display 6”TFT (640×480)
Power supply 220V±10%, 50/60Hz
Li-polymer battery (size (mm): 110x51x16, nominal output voltage: 7.2V, capacity: 5000mAh)
Power line supply (U1, UN), 85V-265V 50/60Hz
Communication port RS232
Test voltage
Range Phase to Netural 0-480V (Phase to Phase 0-830V)
Error ±0.05% (30V-480V)
±0.1% (5V-30V)
Voltage measurement temperature drift < 8 x 10 E-6/K
Voltage measurement relative humidity drift < 8 x 10 E-6/RH
Voltage measurement stability < 50 x10 E-6
Voltage measurement long term stability < 80 x 10 E-6/Year
Harmonic 2nd-64st
Test current
Range (direct connection) 0-12A
Error (direct connection) ±0.05% (100mA-12A)
±0.1% (10mA-100mA)
Range (clamp CT) 10mA-120A
Clamp CT TFT Display RS232 Active Electric Meter Calibration 70Hz Model: Q13
Test range:1mA-120A
Accuracy:0.1%
Ratio:1000:1
Internal diameter:13mm
External diameter:33mm
Lead cable:2.5m
Three phase color label L1=Red,L2=Yellow,L3=Blue
Error (camp CT) ±0.1% (100mA-120A)
Current measurement temperature drift < 8 x 10 E-6/K @ 10mA-120A
Current measurement relative humidity drift < 8 x 10 E-6/RH@ 10mA-120A
Current measurement stability < 50 x10 E-6
Current measurement long term stability < 80 x 10 E-6/Year
Harmonic 2nd-64st
Power & Energy measure error
Active power (direct connection) ±0.05% (0.1A-12A)
±0.1% (0.01A-0.1A)
Reactive power (direct connection) ±0.1% (0.1A-12A)
Energy measure error
Active energy (direct connection) ±0.05% (0.1A-12A)
±0.1% (0.01A-0.1A)
Reactive energy (direct connection) ±0.1% (0.1A-12A)
Power/energy measurement temperature drift < 15 x 10 E-6/K
Power/energy measurement relative humidity drift < 12 x 10 E-6/RH@ 10mA-120A
Power/energy measurement stability < 100 x10 E-6
Power/energy measurement long term stability < 160 x 10 E-6/Year
Error display 5 digits with minimum three decimal places XX.XXX%
Phase angle
Range 0°-360°
Resolution 0.01o
Error ±0.05°
Frequency
Range 40-70Hz
Resolution 0.001Hz
Error 0.002Hz
Pulse input
Input channel 2
Input level 5-24V
Input frequency Max. 2MHz
Pulse output
Energy constant 180000imp/kWh, 1800imp/kWh, 180imp/kWh
Pulse ratio 1:1
Output level 5V
Pulse frequency Standard 400Hz-1KHz, customized max 10KHz
Scanning head
TFT Display RS232 Active Electric Meter Calibration 70Hz TFT Display RS232 Active Electric Meter Calibration 70Hz The sampler is equipped with a bracket which can clip/install on the tested electronic and electromechanical meters, and the sampler can insert to the ‘orifice/slot’ in the center of the bracket.
There are 3 status LED indicator:
[AUTO] – scan the turn-plate of the energy meter
[MANU] –Manual input pulse
[LED] – Receive the LED energy pulse
Function Sensitivity can be intelligently adjusted according to ambient light intensity to ensure accuracy measurement.
Function
Vector diagram Yes
Waveform Yes
Energy accumulation Yes
Communication with PC Yes
Overload protection Yes
2.Cable and Accessories
Test Cable Voltage test cable 1SET Cable Length:2m (R,Y,B,Black)
Current test calbe 1SET Cable Length:2m (R,Y,B,Black)
Plug Pin type 1SET (4black,2Red,2Yellow,2Green)
'U' type 1SET (4black,2Red,2Yellow,2Green)
'Ω' type 1SET (4black,2Red,2Yellow,2Green)
Crocodile type 1SET (1Black,1Red,1Yellow,1Green)
Accessories Bag Yes
3.Mechanical parameters
Instrument dimensions (W×H×D) (mm) 245×162×60
Instrument Weight (kg) 1.8
Carry case dimensions (W×H×D) (mm) 450×320×185
Carry case (kg) 10.6
4.Environmental conditions
Ambient temperature -10°C to 55°C
Relative humidity 15%-95%
Environmental protection level IP51
5.Standard
lsolation protection IEC 61010-1:2001
Energy measurement IEC 60736
Reference standard IEC 62052-11
IEC62053-21
IEC62053-22 & IEC62053-23
IEC61010-1:2001
6.Calibration and maintenance
Warranty 5 years
Calibration Lifelong free calibration service
Recommended calibration interval Every two years

TFT Display RS232 Active Electric Meter Calibration 70Hz


Product Tags:

RS232 Active Electric Meter Calibration

      

TFT Display Electric Meter Calibration

      

Electric Meter Calibration 70Hz

      
China TFT Display RS232 Active Electric Meter Calibration 70Hz wholesale

TFT Display RS232 Active Electric Meter Calibration 70Hz Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)